OEM Parts Cross-Reference Index
190 OEM replacement parts cataloged across 67 error code diagnostic guides in 7 equipment categories. Use this index to cross-reference part numbers, find alternate suppliers, and estimate replacement costs before ordering.
Centrifugal Chillers (61 parts)
| Part Number | Part Name | Est. Price | Associated Error Code |
|---|---|---|---|
00PPG000123 |
Chilled Water Flow Switch | $320 | Carrier 19XR Alarm 201: Low Evaporator... |
025-28678-000 |
Condenser Pressure Transducer | $420 | York YK Centrifugal Chiller Alarm: High... |
031-02430-000 |
OptiView Control Board | $2,800 | York YK Centrifugal Chiller Alarm: High... |
19DV-IGV-ACT |
19DV Inlet Guide Vane Actuator | $2,500-4,000 | Carrier 19DV Alarm: Compressor Surge Detected... |
19DV-PT-DIFF |
19DV Diffuser Pressure Transducer | $400-800 | Carrier 19DV Alarm: Compressor Surge Detected... |
19DV-PU-FD |
19DV Purge Unit Filter/Drier | $200-400 | Carrier 19DV Alarm: Compressor Surge Detected... |
19XR-EXV-ACT |
Electronic Expansion Valve (EXV) Actuator | $1,400 | Carrier 19XR Alarm 105: Low Evaporator... |
19XR-TEMP-004 |
Leaving Chilled Water Temperature Sensor | $220 | Carrier 19XR Alarm 105: Low Evaporator... |
19XR-TEMP-011 |
Evaporator Refrigerant Temperature Sensor | $285 | Carrier 19XR Alarm 105: Low Evaporator... |
BRD0489 |
CH530 Controller EXV Driver Board | $1,400 | Trane CVHE Chiller Alarm 8D: Low Evaporator... |
CH530-MP |
Trane CH530 Main Processor | $1,800-3,500 | Trane CVHF Alarm: Low Evaporator Refrigerant... |
CVHF-OIL-DP-SW |
Oil Pressure Differential Switch | $340 | Trane CVHF Alarm 9A: Oil Pressure Differential... |
CVHF-OIL-FLT-001 |
Oil Filter Cartridge (spin-on type) | $95 | Trane CVHF Alarm 9A: Oil Pressure Differential... |
CVHF-OIL-PUMP-MTR |
Oil Pump Motor Assembly | $2,100 | Trane CVHF Alarm 9A: Oil Pressure Differential... |
Carrier: 19DV-MB-002, Trane: CVHF-MB-003 |
Motor Bearing Assembly | $2,600 | Centrifugal Chiller Alarm Code Comprehensive... |
Carrier: HK05QA003, Trane: CVHE-OP-001 |
Oil Pump Assembly | $850-1,200 | Centrifugal Chiller Alarm Code Comprehensive... |
Carrier: HK05QA128, Trane: CVHE-PS-045 |
Pressure Switch Assembly | $340 | Centrifugal Chiller Alarm Code Comprehensive... |
Carrier: HK05QA210, Trane: CVHE-PT-012 |
Refrigerant Pressure Transducer | $185 | Centrifugal Chiller Alarm Code Comprehensive... |
DKN-3319-07 |
Motor Cooling Refrigerant Filter-Drier | $120 | Daikin WSC Centrifugal Chiller Alarm A07: High... |
DKN-5028-01 |
Motor Winding Temperature Sensor (PTC Thermistor) | $385 | Daikin WSC Centrifugal Chiller Alarm A07: High... |
DKN-WMC-CT150 |
Motor Current Transformer (CT) | $380 | Daikin WMC Chiller Alarm E3: Motor Overcurrent... |
DKN-WMC-MB-STAT |
Magnetic Bearing Stator Assembly | $8,500 | Daikin WMC Alarm E7: Magnetic Bearing... |
DKN-WMC-MBC01 |
Magnetic Bearing Controller Board | $2,600 | Daikin WMC Chiller Alarm E3: Motor Overcurrent... |
DKN-WMC-MBC02 |
Magnetic Bearing Controller (MBC) Unit | $5,200 | Daikin WMC Alarm E7: Magnetic Bearing... |
DKN-WMC-PS600 |
MBC Power Supply (24V DC, 600W) | $1,100 | Daikin WMC Alarm E7: Magnetic Bearing... |
DKN-WMC-VFD300 |
VFD Power Module (IGBT) | $4,200 | Daikin WMC Chiller Alarm E3: Motor Overcurrent... |
FLW-06012 |
Trane Flow Switch (paddle type) | $200-500 | Trane CVHF Alarm: Low Evaporator Refrigerant... |
FLW00217 |
Chilled Water Flow Switch (Paddle Type) | $275 | Trane CVHE Chiller Alarm 8D: Low Evaporator... |
HK05LB401 |
Evaporator Temperature Sensor (Thermistor) | $185 | Carrier 19XR Alarm 201: Low Evaporator... |
HK05QA001 |
Surge Valve Actuator Assembly | $850-1,200 | Carrier 19DV Chiller Alarm 104: Centrifugal... |
HK05QA128 |
Inlet Guide Vane Position Sensor | $340 | Carrier 19DV Chiller Alarm 104: Centrifugal... |
HK05QA210 |
Condenser Water Temperature Sensor | $185 | Carrier 19DV Chiller Alarm 104: Centrifugal... |
HK05QA310 |
Oil Pump Motor Assembly | $1,400 | Carrier 19DV Alarm 102: Low Oil Pressure —... |
HK05QA315 |
Oil Pressure Transducer (0-100 PSID) | $360 | Carrier 19DV Alarm 102: Low Oil Pressure —... |
HK05QA320 |
Oil Filter Element (10-micron) | $85 | Carrier 19DV Alarm 102: Low Oil Pressure —... |
HK06BRG-KIT |
Motor Bearing Set (Journal + Thrust, 19XR) | $6,800 | Carrier 19XR Alarm 125: Motor Bearing High... |
HK06FLT001 |
Motor Cooling Liquid Line Filter Drier | $95 | Carrier 19XR Alarm 125: Motor Bearing High... |
HK06RTD001 |
Motor Bearing RTD Sensor Assembly | $480 | Carrier 19XR Alarm 125: Motor Bearing High... |
JCI-025-43210-001 |
Condenser High Pressure Cutout Switch | $310 | York YK Chiller OptiView Alarm: Condenser High... |
JCI-025-45678-000 |
Condenser Water Temperature Sensor (RTD) | $185-250 | York YK Chiller OptiView Alarm: Condenser High... |
JCI-MTL-BRSH34-10 |
Condenser Tube Brush Set (3/4" tubes, 10-ft handle) | $140 | York YK Chiller OptiView Alarm: Condenser High... |
PRG-CARB-02 |
Purge Unit Carbon Tank | $380 | Trane CVHE Alarm 8A: High Condenser Pressure —... |
SEN01438 |
Evaporator Water Temperature Sensor (Thermistor) | $195 | Trane CVHE Chiller Alarm 8D: Low Evaporator... |
SEN01441 |
Condenser Water Temperature Sensor | $210 | Trane CVHE Alarm 8A: High Condenser Pressure —... |
THM-04812 |
Trane LCHWT Thermistor | $120-250 | Trane CVHF Alarm: Low Evaporator Refrigerant... |
TRN-CTRL-UC800-MOD6 |
UC800 Controller Board (if sensor signal trace is damaged) | $2,800-3,500 | Trane CVHE Chiller Alarm AFT2: Air Flow... |
TRN-HAR08241 |
AFT2 Wiring Harness (sensor-to-UC800) | $95 | Trane CVHE Chiller Alarm AFT2: Air Flow... |
TRN-SEN04162 |
Air Flow Transmitter Sensor Module | $420-580 | Trane CVHE Chiller Alarm AFT2: Air Flow... |
TUBE-BRSH-075 |
Condenser Tube Brush Set (Rotary, 3/4") | $120 | Trane CVHE Alarm 8A: High Condenser Pressure —... |
YK-025-33001-000 |
Oil Temperature Sensor (RTD) | $310 | York YK Chiller Alarm: High Oil Temperature —... |
YK-025-33500-000 |
Oil Level Sensor (Capacitance Type) | $460 | York YK Alarm: Low Oil Level — Oil Management... |
YK-025-34501-002 |
High Pressure Transducer | $420 | York YK Chiller Alarm: Compressor Surge & High... |
YK-029-04512-000 |
Oil Cooler TXV (Thermal Expansion Valve) | $420 | York YK Chiller Alarm: High Oil Temperature —... |
YK-029-04550-SET |
Oil Separator Coalescer Elements (set of 3) | $1,800 | York YK Alarm: Low Oil Level — Oil Management... |
YK-029-05623-000 |
Variable Diffuser Actuator | $1,100 | York YK Chiller Alarm: Compressor Surge & High... |
YK-029-05800-000 |
Oil Eductor Assembly (Venturi Type) | $620 | York YK Alarm: Low Oil Level — Oil Management... |
YK-031-02456-100 |
OptiView Control Board (if surge logging corrupt) | $2,800 | York YK Chiller Alarm: Compressor Surge & High... |
YK-FD-LL |
York Liquid Line Filter/Drier | $180-400 | York YK Chiller Alarm: High Motor Winding... |
YK-HX-OIL-001 |
Oil Cooler Heat Exchanger (Plate Type) | $2,400 | York YK Chiller Alarm: High Oil Temperature —... |
YK-RTD-A |
York Motor RTD Sensor (Phase A) | $150-350 | York YK Chiller Alarm: High Motor Winding... |
YK-TXV-MC |
York Motor Cooling TXV | $800-1,500 | York YK Chiller Alarm: High Motor Winding... |
Commercial Rooftop Units (43 parts)
| Part Number | Part Name | Est. Price | Associated Error Code |
|---|---|---|---|
BRD0521 |
LonWorks Communication Module | $580 | Trane IntelliPak RTU Error ERR12:... |
BRD0525 |
BACnet/IP Gateway Module | $650 | Trane IntelliPak RTU Error ERR12:... |
CBL-CAT6-SH |
Communication Cable (CAT6, Shielded, Outdoor) | $85 | Trane IntelliPak RTU Error ERR12:... |
CRR-HK59ZZ003 |
ABB ACH550 VFD Drive (5HP, 460V) | $1,450-1,900 | Carrier WeatherExpert RTU Alarm E17: Supply... |
CRR-HK59ZZ021 |
VFD Cooling Fan Assembly | $95 | Carrier WeatherExpert RTU Alarm E17: Supply... |
CRR-MTR05002 |
Supply Fan Motor (5HP, 1750 RPM, 460V/3PH) | $680-850 | Carrier WeatherExpert RTU Alarm E17: Supply... |
CWE-CONT-40A |
Compressor Contactor (3-pole, 40A) | $95 | Carrier WeatherExpert RTU Alarm E5: Compressor... |
CWE-FAN-BLT |
Supply Fan Belt (matched set) | $45 | Carrier WeatherExpert RTU Alarm E5: Compressor... |
CWE-OLM-001 |
Compressor Overload Module (external) | $180 | Carrier WeatherExpert RTU Alarm E5: Compressor... |
Carrier: 30RAP-CP-002, Trane: CGAM-CP-001 |
Scroll Compressor Assembly | $2,000-8,000 | RTU Roof Top Unit Diagnostic Guide: Alarm Code... |
Carrier: 30RAP-RL-005, Trane: CGAM-RL-003 |
Refrigerant Line Assembly | $450 | RTU Roof Top Unit Diagnostic Guide: Alarm Code... |
Carrier: WE-FL-001, Trane: IP-FL-002 |
Filter Assembly | $45 | RTU Roof Top Unit Diagnostic Guide: Alarm Code... |
Carrier: WE-FM-012, Trane: IP-FM-008 |
Fan Motor Assembly | $680 | RTU Roof Top Unit Diagnostic Guide: Alarm Code... |
FLT-DR16-410A |
Liquid Line Filter Drier (16 cu in, R-410A) | $55 | Trane RTU Error ERR07: High Compressor... |
FLT0082 |
Return Air Filter Set (MERV 8, 4-pack) | $38 | Trane RTU Error ERR04: Evaporator Frost... |
HH79AC001 |
Economizer Actuator (0-10V, Belimo) | $280 | Carrier WeatherExpert RTU Alarm A005:... |
HH79ECM01 |
Economizer Control Module (W7220) | $420 | Carrier WeatherExpert RTU Alarm A005:... |
HH79NZ047 |
Supply Air Temperature Sensor (10kΩ Type III) | $52 | Carrier WeatherExpert RTU Alarm A001: Supply... |
HH79NZ048 |
Return Air Temperature Sensor (10kΩ Type III) | $55 | Carrier WeatherExpert RTU Alarm A002: Return... |
HH79NZ049 |
Mixed Air Temperature Sensor | $60 | Carrier WeatherExpert RTU Alarm A005:... |
LB-98765A |
Condenser Fan Motor (1/2 HP, 1075 RPM) | $340 | Lennox Energence RTU Alarm 27: High Pressure... |
LB-CAP075-440 |
Fan Motor Run Capacitor (7.5 μF, 440V) | $22 | Lennox Energence RTU Alarm 27: High Pressure... |
LB-HPS650 |
High Pressure Switch (Auto-Reset, 650 PSIG) | $85 | Lennox Energence RTU Alarm 27: High Pressure... |
LB-LPS40 |
Low Pressure Switch (Auto-Reset, 40 PSIG) | $75 | Lennox Energence RTU Alarm 31: Low Suction... |
LB-R410A-25 |
R-410A Refrigerant (25 lb cylinder) | $185 | Lennox Energence RTU Alarm 31: Low Suction... |
LB-SCHR-TL |
Schrader Core Removal Tool (for leak repair) | $45 | Lennox Energence RTU Alarm 31: Low Suction... |
MOT18806 |
ECM Blower Motor Assembly | $1,450 | Trane RTU ECM Blower Motor Alarm:... |
MTR0451 |
Indoor Blower Motor (1.5 HP ECM) | $620 | Trane RTU Error ERR04: Evaporator Frost... |
OPN-RAT-MOD |
i-Vu Controller RAT Input Module | $320 | Carrier WeatherExpert RTU Alarm A002: Return... |
OPN-SAT-MOD |
Carrier i-Vu Controller SAT Input Module | $380 | Carrier WeatherExpert RTU Alarm A001: Supply... |
SEN02133 |
Evaporator Temperature Sensor (10kΩ) | $45 | Trane RTU Error ERR04: Evaporator Frost... |
SEN02145 |
Discharge Line Temperature Sensor (PTC) | $65 | Trane RTU Error ERR07: High Compressor... |
TRN-ACT07540 |
Honeywell MS4120F Economizer Actuator (0-10V, 90° stroke) | $380-520 | Trane IntelliPak RTU Diagnostic 72: Economizer... |
TRN-LNK00112 |
Economizer Linkage Rod Kit (adjustable, stainless steel) | $45 | Trane IntelliPak RTU Diagnostic 72: Economizer... |
TRN-SEN07533 |
Mixed Air Temperature Sensor (10K NTC) | $85 | Trane IntelliPak RTU Diagnostic 72: Economizer... |
WIR0215-6 |
Sensor Wiring Harness (RTU to Controller) | $75 | Carrier WeatherExpert RTU Alarm A001: Supply... |
WIR05002 |
Symbio Communication Cable (Motor to Controller) | $65 | Trane RTU ECM Blower Motor Alarm:... |
YK-025-39012-000 |
Compressor Thermal Overload Module | $175 | York Predator RTU Alarm 3H: Compressor Thermal... |
YK-C40-3P |
Compressor Contactor (3-Pole, 40A) | $120 | York Predator RTU Alarm 3H: Compressor Thermal... |
YK-CBL-MODBUS |
VFD Modbus Communication Cable | $45 | York Predator RTU Alarm 4A: Condenser Fan VFD... |
YK-CCH070 |
Crankcase Heater (70W, 230V) | $65 | York Predator RTU Alarm 3H: Compressor Thermal... |
YK-MTR-CF1 |
Condenser Fan Motor (1 HP, 1075 RPM, TEAO) | $390 | York Predator RTU Alarm 4A: Condenser Fan VFD... |
YK-VFD-CF1 |
Condenser Fan VFD (1 HP, 230V, IP55) | $680 | York Predator RTU Alarm 4A: Condenser Fan VFD... |
Variable Refrigerant Flow VRF (38 parts)
| Part Number | Part Name | Est. Price | Associated Error Code |
|---|---|---|---|
BRC1E63 |
Remote Controller (wired type) | $145 | Daikin VRV A3 Error: Indoor Unit PCB... |
COM-SHIELD-2P |
DIII-NET Communication Wire (Shielded Twisted Pair, per 100m) | $95 | Daikin VRV U4 Error: Indoor-Outdoor... |
COMP-INV-SCROLL |
Inverter Compressor (Scroll, DC Brushless) | $3,200 | Mitsubishi City Multi Error 7102: High... |
DIII-CBL-2C |
DIII-NET Communication Cable (shielded 2-conductor) | $2.50/ft | Daikin VRV A3 Error: Indoor Unit PCB... |
Daikin: VRV-ID-CB-003, Mitsubishi: CM-ID-CB-002 |
Indoor Unit Controller Board | $680 | VRF Variable Refrigerant Flow System Guide:... |
Daikin: VRV-OD-MPCB-001, Mitsubishi: CM-OD-MPCB-001 |
Outdoor Unit Main PCB | $2,600 | VRF Variable Refrigerant Flow System Guide:... |
Daikin: VRV-PIP-002, Mitsubishi: CM-PIP-001 |
Refrigerant Pipe Assembly | $850 per 50ft | VRF Variable Refrigerant Flow System Guide:... |
Daikin: VRV-PS-012, Mitsubishi: CM-PS-008 |
Pressure Sensor Assembly | $420 | VRF Variable Refrigerant Flow System Guide:... |
EBG61294001 |
Pressure Sensor Wiring Harness | $85 | LG Multi V CH74 Error: High Pressure Sensor... |
EBG61312801 |
High Pressure Sensor (4-20mA, 0-5.0 MPa) | $210 | LG Multi V Error CH24: High Pressure Sensor Malfunction |
EBG61322701 |
High Pressure Sensor (Transducer) | $310 | LG Multi V CH74 Error: High Pressure Sensor... |
EBR83257801 |
Outdoor Unit Main PCB (Gen 4) | $1,600 | LG Multi V Error CH24: High Pressure Sensor Malfunction |
EBR83257802 |
Inverter Drive IPM (Intelligent Power Module) | $2,400 | LG Multi V Error CH34: Inverter Compressor... |
EBR83257810 |
Inverter Compressor (DC Brushless Scroll) | $3,800 | LG Multi V Error CH34: Inverter Compressor... |
EBR83257811 |
Pressure Sensor Connector Harness | $35 | LG Multi V Error CH24: High Pressure Sensor Malfunction |
EBR83257820 |
DC Link Capacitor Bank | $680 | LG Multi V Error CH34: Inverter Compressor... |
EKPCAVJU-COIL |
Outdoor Coil (Microchannel, 4-row) | $2,100 | Daikin VRV E3 Error: High Pressure Switch... |
EKPCAVJU-FAN |
Outdoor Unit Fan Motor (ECM, 850W) | $980 | Daikin VRV E3 Error: High Pressure Switch... |
EKPCAVJU-HPS |
High Pressure Switch HPS1 (Auto-Reset, 601 PSIG) | $150 | Daikin VRV E3 Error: High Pressure Switch... |
EKPCAVJU6 |
Outdoor Unit Main PCB (DIII-NET) | $1,800 | Daikin VRV U4 Error: Indoor-Outdoor... |
EKPCB036A |
Outdoor Unit Main PCB (with power supply monitoring) | $1,850 | Daikin VRV U2 Error: Power Supply Voltage... |
EKR007 |
Phase Monitor Relay | $245 | Daikin VRV U2 Error: Power Supply Voltage... |
KRP928A2S |
Indoor Unit PCB Communication Adapter | $380 | Daikin VRV U4 Error: Indoor-Outdoor... |
LEV-OUT-410A |
Linear Expansion Valve (LEV) — Outdoor Unit | $420 | Mitsubishi City Multi Error 7102: High... |
MTR-OU-750ECM |
Outdoor Unit Fan Motor (ECM, 750W) | $1,100 | Mitsubishi City Multi Error 7100: High... |
PCB-IND-A3-DAIK |
Indoor Unit Control PCB | $420-680 | Daikin VRV A3 Error: Indoor Unit PCB... |
R65B45673 |
High Pressure Sensor (HPS) 0-4.5 MPa | $295 | Mitsubishi City Multi Error 7100: High... |
R65B45681 |
Discharge Temperature Thermistor (100kΩ) | $80 | Mitsubishi City Multi Error 7102: High... |
R65B45700 |
Inverter Power Module (IPM, 3-Phase Output) | $2,600 | Mitsubishi City Multi Error 5100: Inverter... |
R65B45710 |
Compressor Start Capacitor (if PSC assist) | $90 | Mitsubishi City Multi Error 5100: Inverter... |
R65B45720 |
DC Reactor (Line Filter, 3-Phase) | $520 | Mitsubishi City Multi Error 5100: Inverter... |
RBC-AS21E |
TCC-LINK Remote Controller (Wired) | $195 | Toshiba SMMS U1 Error: Indoor Unit Address Duplication |
TCC-ADDR-TOOL |
TCC-LINK Address Setting Tool (Handheld) | $150 | Toshiba SMMS U1 Error: Indoor Unit Address Duplication |
TCC-LINK-PCB3 |
Indoor Unit PCB (TCC-LINK) | $280 | Toshiba SMMS U1 Error: Indoor Unit Address Duplication |
TCC-MAIN-PCB5 |
Outdoor Unit Main PCB (TCC-LINK Master) | $1,900 | Toshiba SMMS U4 Error: Outdoor Unit PCB... |
TCC-PS-16V |
TCC-LINK Bus Power Supply Module (16V DC) | $340 | Toshiba SMMS U4 Error: Outdoor Unit PCB... |
TCC-TERM-KIT |
TCC-LINK Bus Termination Resistor Kit | $30 | Toshiba SMMS U4 Error: Outdoor Unit PCB... |
THM-OUT-SET3 |
Outdoor Coil Thermistor Assembly (set of 3) | $120 | Mitsubishi City Multi Error 7100: High... |
Scroll Chillers (39 parts)
| Part Number | Part Name | Est. Price | Associated Error Code |
|---|---|---|---|
025-48872-000 |
Chilled Water Flow Switch (paddle type) | $245 | York YLAA Scroll Chiller Alarm B4: Brazed... |
025-48873-001 |
Leaving Chilled Water Thermistor (10K Type II) | $68 | York YLAA Scroll Chiller Alarm B4: Brazed... |
Carrier: 30RAP-CC-003, Trane: CGAM-CC-002 |
Condenser Coil Assembly | $1,200 | Scroll Chiller Diagnostic Protocol: Alarm Code... |
Carrier: 30RAP-OP-001, Trane: CGAM-OP-002 |
Oil Pump Assembly | $850 | Scroll Chiller Diagnostic Protocol: Alarm Code... |
Carrier: 30RAP-RL-005, Trane: CGAM-RL-003 |
Refrigerant Line Assembly | $450 | Scroll Chiller Diagnostic Protocol: Alarm Code... |
Carrier: 30RAP-SCP-001, Trane: CGAM-SCP-002 |
Scroll Compressor Assembly | $2,000-8,000 | Scroll Chiller Diagnostic Protocol: Alarm Code... |
Consult factory for model-specific |
Brazed Plate Heat Exchanger (BPHE) Replacement | $3,500-8,000 | York YLAA Scroll Chiller Alarm B4: Brazed... |
DKN-CONT-40 |
Compressor Contactor (3-Pole, 40A with 24V Coil) | $140 | Daikin McQuay AGZ Alarm E3: Compressor Motor... |
DKN-FLOW-SW |
Differential Pressure Flow Switch (Field-Adjustable) | $225 | Daikin McQuay AGZ Chiller Alarm E1: Evaporator... |
DKN-MT3-FLOW |
MicroTech III Controller Flow Input Module | $580 | Daikin McQuay AGZ Chiller Alarm E1: Evaporator... |
DKN-OLR-010 |
Compressor Overload Relay (Manual Reset, Class 10) | $160 | Daikin McQuay AGZ Alarm E3: Compressor Motor... |
DKN-PUMP-CONT |
Chilled Water Pump Contactor (with Aux Contact) | $165 | Daikin McQuay AGZ Chiller Alarm E1: Evaporator... |
DMQ-SEN06610 |
Low Pressure Transducer (0-200 psig, 0-5V output) | $210-280 | Daikin McQuay AGZ Scroll Chiller Alarm LOC:... |
DMQ-TL00012 |
Schrader Core Removal Tool + Replacement Cores (kit of 5) | $60 | Daikin McQuay AGZ Scroll Chiller Alarm LOC:... |
FLT-DR16 |
Liquid Line Filter Drier (16 cu in) | $45 | Trane CGAM Scroll Chiller Alarm LPC: Low... |
HK05EXV045 |
Electronic Expansion Valve (EXV) Body | $520 | Carrier AquaSnap 30RAP Alarm 55: Low Suction... |
HK05FL019 |
Chilled Water Flow Switch | $195 | Carrier AquaSnap 30RAP Alarm 55: Low Suction... |
HK05YZ012 |
Suction Pressure Transducer (0-200 PSIG) | $280 | Carrier AquaSnap 30RAP Alarm 55: Low Suction... |
HK05YZ025 |
High Pressure Switch (Manual Reset, 650 PSIG) | $95 | Carrier AquaSnap 30RAP Alarm 51: High Pressure... |
HK05YZ030 |
Condenser Fan Motor (1/2 HP, 1075 RPM) | $340 | Carrier AquaSnap 30RAP Alarm 51: High Pressure... |
HK05YZ035 |
Condenser Fan Motor Run Capacitor | $28 | Carrier AquaSnap 30RAP Alarm 51: High Pressure... |
HK05YZ040 |
Entering Chilled Water Temperature Sensor | $195 | Carrier AquaSnap 30RAP Alarm 52: Circuit... |
HK05YZ045 |
EXV Control Board (Defrost Logic) | $520 | Carrier AquaSnap 30RAP Alarm 52: Circuit... |
N/A (supply house) |
R-410A Refrigerant (25 lb cylinder) | $180-220 | Daikin McQuay AGZ Scroll Chiller Alarm LOC:... |
Not serviceable separately |
Compressor Internal Protector Module (Embedded) | Included with compressor replacement ($3,500-6,000) | Trane CGAM Scroll Chiller Alarm OVL:... |
TDR-CCH100 |
Crankcase Heater (100W, 460V) | $75 | Trane CGAM Scroll Chiller Alarm OVL:... |
TDR-CONT30 |
Condenser Fan Motor Contactor (3-Pole, 30A) | $85 | Trane CGAM Alarm HPC: High Pressure Cutout —... |
TDR00345 |
Low Pressure Transducer (0-150 PSIG) | $260 | Trane CGAM Scroll Chiller Alarm LPC: Low... |
TDR00346 |
High Pressure Cutout Switch (Auto-Reset) | $110 | Trane CGAM Alarm HPC: High Pressure Cutout —... |
VAL-TXV15 |
Thermal Expansion Valve (TXV, 15-ton) | $380 | Trane CGAM Scroll Chiller Alarm LPC: Low... |
YK-CAP-BANK3 |
Run Capacitor Bank (set of 3, 60 μF each) | $240 | York YLAA Scroll Chiller Alarm B2: Compressor... |
YK-CONT50 |
Compressor Contactor (3-Pole, 50A with Aux) | $185 | York YLAA Scroll Chiller Alarm B2: Compressor... |
YK-CONT50-3P |
Compressor Contactor (3-Pole, 50A) | $185 | York YLAA Scroll Chiller Alarm B5: Phase Loss... |
YK-FUSE-200A |
Main Power Fuse Block (200A, 600V) | $350 | York YLAA Scroll Chiller Alarm B5: Phase Loss... |
YK-OLR-010 |
Compressor Overload Relay (Class 10) | $145 | York YLAA Scroll Chiller Alarm B2: Compressor... |
YK-PMR-3PH |
Phase Monitor Relay (3-Phase, 208-480V) | $260 | York YLAA Scroll Chiller Alarm B5: Phase Loss... |
YLAA-AMB-SEN-001 |
Ambient Temperature Sensor (thermistor type) | $65 | York YLAA Alarm B7: Ambient Temperature Sensor... |
YLAA-IO-MOD-002 |
OptiView Controller I/O Module | $420 | York YLAA Alarm B7: Ambient Temperature Sensor... |
YLAA-SEN-CBL-4C |
Sensor Cable Assembly (4-conductor shielded) | $12/ft | York YLAA Alarm B7: Ambient Temperature Sensor... |
Commercial Rooftop Units (RTU) (2 parts)
| Part Number | Part Name | Est. Price | Associated Error Code |
|---|---|---|---|
50DK500432 |
Sensor Wiring Harness (3-pin Weatherpack) | $28 | Carrier WeatherExpert RTU Alarm S07: Outdoor... |
HH79NZ039 |
Outdoor Air Temperature Sensor (10K Type II Thermistor) | $62 | Carrier WeatherExpert RTU Alarm S07: Outdoor... |
Variable Refrigerant Flow (VRF) (3 parts)
| Part Number | Part Name | Est. Price | Associated Error Code |
|---|---|---|---|
Belden 9841 or equivalent |
Shielded Twisted Pair Cable (M-NET spec) | $0.85/ft | Mitsubishi City Multi PURY-S U9 Error:... |
PAC-SC51KUA |
M-NET Power Supply Unit (PAC-SC51KUA) | $315 | Mitsubishi City Multi PURY-S U9 Error:... |
PUHY-PCB-MNET |
M-NET Communication PCB (Outdoor Unit) | $790 | Mitsubishi City Multi PURY-S U9 Error:... |
Maintenance (4 parts)
| Part Number | Part Name | Est. Price | Associated Error Code |
|---|---|---|---|
Carrier: HK05-OIL-002, Trane: CVHE-OIL-001 |
Compressor Oil | $120 per gallon | HVAC Preventive Maintenance Schedule Guide:... |
Carrier: WE-FL-001, Trane: IP-FL-002 |
Filter Assembly | $45-85 | HVAC Preventive Maintenance Schedule Guide:... |
Carrier: WE-FM-012, Trane: IP-FM-008 |
Fan Motor Assembly | $680 | HVAC Preventive Maintenance Schedule Guide:... |
Generic: Alkaline-based coil cleaner |
Coil Cleaning Chemicals | $35 per gallon | HVAC Preventive Maintenance Schedule Guide:... |