HVAC Error Code Lookup — Commercial
& Residential Diagnostic Database

Look up HVAC error codes and alarm diagnostics for Carrier, Trane, York, Daikin, Lennox, and Mitsubishi systems. Commercial chiller alarms, RTU fault codes, residential AC troubleshooting, OEM part numbers, and energy waste cost estimator — fix it faster, lower the electric bill.

Centrifugal Chillers Commercial Rooftop Units Variable Refrigerant Flow VRF Scroll Chillers Commercial Rooftop Units (RTU) Variable Refrigerant Flow (VRF)

Centrifugal Chillers

18 specification sheets

Commercial HVAC material specifications, cross-references, and insurance claim guidelines.

Centrifugal Chillers

Carrier 19DV Chiller Alarm 104: Centrifugal Compressor Surge Diagnosis

Alarm 104 on the Carrier 19DV centrifugal chiller indicates a compressor surge condition — a...

Centrifugal Chillers

York YK Chiller Alarm: Compressor Surge & High Lift Protection

The York YK centrifugal chiller features an advanced surge protection algorithm that monitors...

Centrifugal Chillers

Daikin WMC Chiller Alarm E3: Motor Overcurrent & VFD Fault

Daikin WMC chillers use oil-free magnetic bearing centrifugal compressors with integrated...

View all 18 Centrifugal Chillers specs →

Commercial Rooftop Units

14 specification sheets

Commercial HVAC material specifications, cross-references, and insurance claim guidelines.

Commercial Rooftop Units

Trane RTU Error ERR04: Evaporator Frost Protection Active

The ERR04 code on Trane Precedent and Voyager commercial rooftop units triggers when the...

Commercial Rooftop Units

Carrier WeatherExpert RTU Alarm A001: Supply Air Temperature Sensor Failure

Alarm A001 on the Carrier WeatherExpert series indicates that the supply air temperature (SAT)...

Commercial Rooftop Units

Lennox Energence RTU Alarm 27: High Pressure Cutout — Condenser Fan Failure

Alarm 27 on Lennox Energence 6-25 ton commercial rooftop units is a high-pressure cutout...

View all 14 Commercial Rooftop Units specs →

Variable Refrigerant Flow VRF

12 specification sheets

Commercial HVAC material specifications, cross-references, and insurance claim guidelines.

Variable Refrigerant Flow VRF

Daikin VRV U4 Error: Indoor-Outdoor Communication Failure

The U4 error on Daikin VRV systems indicates a communication failure on the DIII-NET bus between...

Variable Refrigerant Flow VRF

Mitsubishi City Multi Error 7100: High Pressure Protection — Outdoor Unit

Error 7100 on Mitsubishi Electric City Multi VRF systems indicates that the high-pressure sensor...

Variable Refrigerant Flow VRF

LG Multi V Error CH24: High Pressure Sensor Malfunction

Error CH24 on LG Multi V VRF systems indicates that the high-pressure sensor signal is out of...

View all 12 Variable Refrigerant Flow VRF specs →

Scroll Chillers

12 specification sheets

Commercial HVAC material specifications, cross-references, and insurance claim guidelines.

Scroll Chillers

Carrier AquaSnap 30RAP Alarm 55: Low Suction Pressure — Freeze Protection

Alarm 55 on the Carrier AquaSnap 30RAP air-cooled scroll chiller indicates that the suction...

Scroll Chillers

Trane CGAM Scroll Chiller Alarm LPC: Low Pressure Cutout — Circuit 1

The Low Pressure Cutout (LPC) alarm on Trane CGAM air-cooled scroll chillers protects the...

Scroll Chillers

York YLAA Scroll Chiller Alarm B2: Compressor Motor Overload

Alarm B2 on the York YLAA air-cooled scroll chiller indicates that a compressor motor overload...

View all 12 Scroll Chillers specs →

Commercial Rooftop Units (RTU)

1 specification sheets

Commercial HVAC material specifications, cross-references, and insurance claim guidelines.

Commercial Rooftop Units (RTU)

Carrier WeatherExpert RTU Alarm S07: Outdoor Air Temperature Sensor Fault

Alarm S07 on Carrier WeatherExpert rooftop units indicates a fault in the outdoor air...

View all 1 Commercial Rooftop Units (RTU) specs →

Variable Refrigerant Flow (VRF)

1 specification sheets

Commercial HVAC material specifications, cross-references, and insurance claim guidelines.

Variable Refrigerant Flow (VRF)

Mitsubishi City Multi PURY-S U9 Error: Indoor-Outdoor Transmission Fault

U9 on Mitsubishi City Multi PURY-S systems is a transmission error between the outdoor unit and...

View all 1 Variable Refrigerant Flow (VRF) specs →

Why LowersHVAC?

40 Error Codes Across 6 Equipment Types

Diagnostic guides covering Carrier, Trane, York, Daikin, Lennox, Mitsubishi Electric — centrifugal chillers, RTUs, VRF systems, and scroll chillers. Each guide includes OEM part numbers, step-by-step troubleshooting, and 8+ field-verified diagnoses by James Walker, NATE-Certified Senior Commercial HVAC Service Technician.

Interactive Diagnostic Terminal

Click-to-expand troubleshooting steps built for technicians on the job. Each diagnostic procedure follows manufacturer service manual logic — verify before replacing, test before condemning. Works on your phone while you're on the roof.

Energy Waste Calculator Built In

Every error code page includes a fault-induced energy waste estimator. Calculate what that chiller alarm or RTU fault is costing in electricity — then use the OEM parts table to price the fix. Troubleshoot faster, lower the bill.