Did you know that 75% of HVAC breakdowns are caused by a lack of maintenance?
Your heating and cooling system is like a car. If you never change the oil or check the tires, it will eventually break down on the side of the road (or in this case, leave you freezing in January).
Regular maintenance doesn’t just prevent breakdowns; it saves you money. A tuned-up system runs more efficiently, lowering your monthly energy bills by up to 30%.
At LowersHVAC, we believe in empowering homeowners. This guide breaks down exactly what you can do yourself (DIY) and what requires a certified professional.
⏰ Overdue for a Tune-Up?
Don’t wait for your system to fail. Professional maintenance pays for itself in energy savings.
👉 [Get 3 Free Maintenance Quotes from Local Pros] (Link to Angi)
1. The Cost of Neglect
Why spend money on maintenance? Because not doing it costs more. Here is the math:
| Scenario | Estimated Cost | Lifespan Impact |
| Annual Maintenance | $79 – $150 / year | ✅ Extends life to 15-20 years |
| Neglected System | $0 / year | ❌ Reduces life to 8-10 years |
| Result of Neglect | $400+ Emergency Repairs | Premature Replacement ($5k+) |
2. Spring/Summer Checklist (AC Focus)
Before the summer heat hits, run through this list to ensure your Air Conditioner is ready.
✅ DIY Tasks (Safe for Homeowners)
-
Change the Air Filter: Do this every 1-3 months. A dirty filter suffocates your AC.
-
Clear Debris: Remove leaves, grass clippings, and dirt from around the outdoor condenser unit. Keep 2 feet of clearance.
-
Check Thermostat: Switch it to “COOL” and run a test. Replace batteries if needed.
-
Clean Registers: Wipe down indoor vents and make sure they aren’t blocked by furniture or curtains.
🛠️ Professional Tasks (Requires a Tech)
-
Check Refrigerant Levels: Low Freon/Puron means a leak. You cannot fix this yourself.
-
Clean Evaporator Coils: These are deep inside the unit and require special chemicals.
-
Inspect Electrical Wiring: Tighten loose connections and measure voltage/amperage to prevent fire hazards.
-
Flush Condensate Drain: Pros use pressurized gas to clear algae and prevent water damage.
⚠️ Need a Pro Check-up?
If your AC isn’t blowing ice-cold air during your test run, you need a diagnostic.
📞 Call Dispatch: <a href=”tel:+13234058890″ style=”color:#d35400;”>(323) 405-8890</a>
3. Fall/Winter Checklist (Furnace Focus)
When the leaves start to fall, it’s time to switch gears to heating.
✅ DIY Tasks (Safe for Homeowners)
-
Replace the Filter: Yes, again. Winter filters clog faster due to increased indoor time.
-
Check Carbon Monoxide Detectors: Test them and replace batteries. This saves lives.
-
Open Vents: Ensure all heat registers are open to allow proper airflow.
-
Listen for Noises: Turn on the furnace. Banging? Screeching? Note it down.
🛠️ Professional Tasks (Requires a Tech)
-
Heat Exchanger Inspection: A cracked heat exchanger releases deadly carbon monoxide. Only a pro can check this safely.
-
Burner Cleaning: Cleaning soot off the burners ensures efficient combustion.
-
Igniter/Pilot Light Check: Ensuring the system lights reliably every time.
-
Lubricate Blower Motor: Reduces friction and extends the motor’s life.

4. Maintenance Plans vs. One-Time Visits
Most contractors offer an annual “Service Contract” or “Maintenance Plan.” Is it worth it?
| Feature | One-Time Tune-Up | Annual Service Plan |
| Cost | $99 – $150 per visit | $150 – $300 / year |
| Visits Included | 1 | 2 (Spring & Fall) |
| Priority Service | No | ✅ Yes (Skip the line) |
| Parts Discount | None | ✅ Usually 10-15% off |
| Warranty | Standard | ✅ Often extended |
Verdict: If your system is over 5 years old, a Service Plan is usually the smarter financial choice.
5. What You Should NEVER DIY
We love DIY, but HVAC systems involve high voltage electricity, flammable gas, and high-pressure chemicals.
🚫 DO NOT attempt to:
-
Recharge Refrigerant: It is illegal without an EPA license.
-
Fix a Gas Leak: If you smell gas, leave the house and call 911.
-
Repair Electrical Boards: One wrong touch can fry your system or shock you.